Resultados 1 - 20 de 1.346
Filtrar
1.
BMC Med Imaging ; 24(1): 94, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649862

RESUMO

BACKGROUND: Large field of view CZT SPECT cameras with a ring geometry are available for some years now. Thanks to their good sensitivity and high temporal resolution, general dynamic SPECT imaging may be performed more easily, without resorting to dedicated systems. To evaluate the dynamic SPECT imaging by such cameras, we have performed an in vivo pilot study to analyze the kidney function of a pig and compare the results to standard dynamic planar imaging by a conventional gamma camera. METHODS: A 7-week-old (12 kg) female Landrace pig was injected with [99mTc]Tc-MAG3 and a 30 min dynamic SPECT acquisition of the kidneys was performed on a CZT ring camera. A fast SPECT/CT was acquired with the same camera immediately after the dynamic SPECT, without moving the pig, and used for attenuation correction and drawing regions of interest. The next day the same pig underwent a dynamic planar imaging of the kidneys by a conventional 2-head gamma camera. The dynamic SPECT acquisition was reconstructed using a MLEM algorithm with up to 20 iterations, with and without attenuation correction. Time-activity curves of the total counts of each kidney were extracted from 2D and 3D dynamic images. An adapted 2-compartment model was derived to fit the data points and extract physiological parameters. Comparison of these parameters was performed between the different reconstructions and acquisitions. RESULTS: Time-activity curves were nicely fitted with the 2-compartment model taking into account the anesthesia and bladder filling. Kidney physiological parameters were found in agreement with literature values. Good agreement of these parameters was obtained for the right kidney between dynamic SPECT and planar imaging. Regional analysis of the kidneys can be performed in the case of the dynamic SPECT imaging and provided good agreement with the whole kidney results. CONCLUSIONS: Dynamic SPECT imaging is feasible with CZT swiveling-detector ring cameras and provides results in agreement with dynamic planar imaging by conventional gamma cameras. Regional analysis of organs uptake and clearance becomes possible. Further studies are required regarding the optimization of acquisition and reconstruction parameters to improve image quality and enable absolute quantification.


Assuntos
Câmaras gama , Rim , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único , Zinco , Animais , Projetos Piloto , Rim/diagnóstico por imagem , Feminino , Suínos , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Cádmio , Tecnécio Tc 99m Mertiatida , Algoritmos , Compostos Radiofarmacêuticos
2.
Appl Radiat Isot ; 181: 110056, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34953318

RESUMO

Boron Neutron Capture Therapy (BNCT) is a promising cancer therapy, which has recently been in practical use in Japan especially using an accelerator. In BNCT real-time measurement of local boron dose is required. In the present study, a novel design of a SPECT system for BNCT (BNCT-SPECT) has been carried out to realize estimation of the local boron dose, i.e., treatment effect of BNCT. Necessary performance which BNCT community requires includes accuracy of 5% and spatial resolution of 5 mm, which are regarded to be difficult to realize. A possible design was investigated to meet the requirements. The design results we achieved are as follows: As for the elemental detection device, GAGG (3.5 × 3.5 × 30 mm3) was selected, and for the collimator, the collimator hole diameter was 3.5 mm, the collimator hole pitch was 4 mm and the collimator length was 26 cm. For the obtained performance with the design, the accuracy was 4.4% and the spatial resolution was 5.1 mm. Currently prior to production of the real system, a prototype of BNCT-SPECT is being developed to acquire real projection data to confirm the performance and examine our own image reconstruction method with the obtained projection data.


Assuntos
Compostos de Boro/administração & dosagem , Terapia por Captura de Nêutron de Boro , Contagem de Cintilação , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Humanos , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Aceleradores de Partículas , Dosagem Radioterapêutica , Tomografia Computadorizada de Emissão de Fóton Único/métodos
3.
Phys Med Biol ; 66(6): 065011, 2021 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-33578400

RESUMO

Despite improvements in small animal PET instruments, many tracers cannot be imaged at sufficiently high resolutions due to positron range, while multi-tracer PET is hampered by the fact that all annihilation photons have equal energies. Here we realize multi-isotope and sub-mm resolution PET of isotopes with several mm positron range by utilizing prompt gamma photons that are commonly neglected. A PET-SPECT-CT scanner (VECTor/CT, MILabs, The Netherlands) equipped with a high-energy cluster-pinhole collimator was used to image 124I and a mix of 124I and 18F in phantoms and mice. In addition to positrons (mean range 3.4 mm) 124I emits large amounts of 603 keV prompt gammas that-aided by excellent energy discrimination of NaI-were selected to reconstruct 124I images that are unaffected by positron range. Photons detected in the 511 keV window were used to reconstruct 18F images. Images were reconstructed iteratively using an energy dependent matrix for each isotope. Correction of 18F images for contamination with 124I annihilation photons was performed by Monte Carlo based range modelling and scaling of the 124I prompt gamma image before subtracting it from the 18F image. Additionally, prompt gamma imaging was tested for 89Zr that emits very high-energy prompts (909 keV). In Derenzo resolution phantoms 0.75 mm rods were clearly discernable for 124I, 89Zr and for simultaneously acquired 124I and 18F imaging. Image quantification in phantoms with reservoirs filled with both 124I and 18F showed excellent separation of isotopes and high quantitative accuracy. Mouse imaging showed uptake of 124I in tiny thyroid parts and simultaneously injected 18F-NaF in bone structures. The ability to obtain PET images at sub-mm resolution both for isotopes with several mm positron range and for multi-isotope PET adds to many other unique capabilities of VECTor's clustered pinhole imaging, including simultaneous sub-mm PET-SPECT and theranostic high energy SPECT.


Assuntos
Elétrons , Aceleradores de Partículas , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Raios gama , Radioisótopos do Iodo , Camundongos , Método de Monte Carlo , Imagens de Fantasmas , Fótons , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada por Raios X/instrumentação
4.
Phys Med Biol ; 66(3): 035007, 2021 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-33065564

RESUMO

With brain-dedicated multi-detector systems employing pinhole apertures the usage of detectors facing the top of the patient's head (i.e. quasi-vertex (QV) views) can provide the advantage of additional viewing from close to the brain for improved detector coverage. In this paper, we report the results of simulation and reconstruction studies to investigate the impact of the QV views on the imaging performance of AdaptiSPECT-C, a brain-dedicated stationary SPECT system under development. In this design, both primary and scatter photons from regions located inferior to the brain can contribute to SPECT projections acquired by the QV views, and thus degrade AdaptiSPECT-C imaging performance. In this work, we determined the proportion, origin, and nature (i.e. primary, scatter, and multiple-scatter) of counts emitted from structures within the head and throughout the body contributing to projections from the different AdaptiSPECT-C detector rings, as well as from a true vertex view detector. We simulated phantoms used to assess different aspects of image quality (i.e. uniform activity concentration sphere, and Derenzo), as well as anthropomorphic phantoms with different count levels emulating clinical 123I activity distributions (i.e. DaTscan and perfusion). We determined that attenuation and scatter in the patient's body greatly diminish the probability of the photons emitted outside the volume of interest reaching to detectors and being recorded within the 15% photopeak energy window. In addition, we demonstrated that the inclusion of the residual of such counts in the system acquisition does not degrade visual interpretation or quantitative analysis. The addition of the QV detectors improves volumetric sensitivity, angular sampling, and spatial resolution leading to significant enhancement in image quality, especially in the striato-thalamic and superior regions of the brain. Besides, the use of QV detectors improves the recovery of clinically relevant metrics such as the striatal binding ratio and mean activity in selected cerebral structures. Our findings proving the usefulness of the QV ring for brain imaging with 123I agents can be generalized to other commonly used SPECT imaging agents labelled with isotopes, such as 99mTc and likely 111In.


Assuntos
Encéfalo/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Fótons , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
5.
J Nucl Cardiol ; 28(5): 2299-2309, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-31997101

RESUMO

BACKGROUND: In recent years, with the advance of myocardial blood flow (MBF) measurement capability in dynamic single photon emission computerized tomography (SPECT) systems, significant effort has been devoted to validation of the new capability. Unfortunately, the mechanical phantoms available for the validation process lack essential features-they either have a constant radiotracer concentration or they have rigid (static) walls unable to simulate cardiac beating. METHODS AND RESULTS: We have developed a mechanical cardiac phantom that is able to mimic physiological radiotracer variation in the left ventricle (LV) cavity and in the myocardium (M), while performing beating-like motion. We have also developed a mathematical model of the phantom, allowing a description of the radiotracer concentrations in both regions (LV, M) as a function of time, which served as a tool for experiment planning and to accurately mimic physiological-like time-activity curves (TACs). A net retention model for the phantom was also developed, which served to compute the theoretical (i.e., expected) MBF of the phantom from measured quantities only, and thus validate the MBF reported by the SPECT system. In this paper, phantom experiments were performed on a GE Discovery NM 530c SPECT system. CONCLUSIONS: A novel dynamic cardiac phantom for emission tomography has been developed. The new phantom is capable of producing a wide range of TACs that can mimic physiological (and potentially in the future, pathological) curves, similar to those observed in dynamic SPECT systems. SPECT-reported MBF values were validated against known (measured) activity of the injected radiotracer from phantom experiments, which allowed to determine the accuracy of the GE Discovery 530c SPECT system.


Assuntos
Reserva Fracionada de Fluxo Miocárdico/fisiologia , Modelos Cardiovasculares , Imagem de Perfusão do Miocárdio/instrumentação , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Humanos , Compostos Radiofarmacêuticos/administração & dosagem , Reprodutibilidade dos Testes
7.
Ann Nucl Med ; 35(1): 47-58, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33068288

RESUMO

PURPOSE: The aim of this work was to develop a digital dynamic cardiac phantom able to mimic gated myocardial perfusion single photon emission computed tomography (SPECT) images. METHODS: A software code package was written to construct a cardiac digital phantom based on mathematical ellipsoidal model utilizing powerful numerical and mathematic libraries of python programing language. An ellipsoidal mathematical model was adopted to create the left ventricle geometrical volume including myocardial boundaries, left ventricular cavity, with incorporation of myocardial wall thickening and motion. Realistic myocardial count density from true patient studies was used to simulate statistical intensity variation during myocardial contraction. A combination of different levels of defect extent and severity were precisely modeled taking into consideration defect size variation during cardiac contraction. Wall thickening was also modeled taking into account the effect of partial volume. RESULTS: It has been successful to build a python-based software code that is able to model gated myocardial perfusion SPECT images with variable left ventricular volumes and ejection fraction. The recent flexibility of python programming enabled us to manipulate the shape and control the functional parameters in addition to creating variable sized-defects, extents and severities in different locations. Furthermore, the phantom code also provides different levels of image filtration mimicking those filters used in image reconstruction and their influence on image quality. Defect extent and severity were found to impact functional parameter estimation in consistence to clinical examinations. CONCLUSION: A python-based gated myocardial perfusion SPECT phantom has been successfully developed. The phantom proved to be reliable to assess cardiac software analysis tools in terms of perfusion and functional parameters. The software code is under further development and refinement so that more functionalities and features can be added.


Assuntos
Coração/diagnóstico por imagem , Imagens de Fantasmas , Software , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Processamento de Imagem Assistida por Computador
8.
J Nucl Cardiol ; 28(6): 3025-3037, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33000403

RESUMO

BACKGROUND: Myocardial perfusion imaging (MPI) with a novel D-SPECT camera maintains excellent prognostic value compared to conventional SPECT. However, information about the relationship between D-SPECT MPI and the prognosis in patients with ischemia and no obstructive coronary artery disease (INOCA) is limited. The objective of this study was to evaluate the prognostic value of MPI with D-SPECT in INOCA and obstructive coronary artery disease (CAD) patients. METHODS: All consecutive patients with suspected CAD and without prior CAD who underwent D-SPECT MPI and invasive coronary angiography within 3 months were considered. INOCA and obstructive CAD were defined as < 50% and ≥ 50% coronary stenosis, respectively. Patients were followed-up for the occurrence of major adverse cardiac events (MACE: cardiovascular death, nonfatal myocardial infarction, revascularization, stroke, heart failure and angina-related rehospitalization). RESULTS: Among 506 patients, 232 (45.8%) were INOCA patients. A total of 33.2% of the INOCA patients had abnormal D-SPECT MPI, whereas 77.7% of the obstructive CAD patients had abnormal D-SPECT MPI. In both groups, patients with abnormal D-SPECT MPI demonstrated higher MACE rates and lower survival free of MACE. In addition, patients with INOCA and abnormal D-SPECT MPI had a poor prognosis similar to that of the obstructive CAD patients. Cox regression analysis showed that the risk-adjusted hazard ratios for abnormal D-SPECT MPI were 2.55 [1.11-5.87] and 2.06 [1.03-4.10] in the INOCA and obstructive CAD patients, respectively. CONCLUSIONS: D-SPECT MPI provides excellent prognostic information, with a more severe prognosis in patients with abnormal D-SPECT MPI. INOCA patients with abnormal D-SPECT MPI experience a poor prognosis similar to that of patients with obstructive CAD.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Isquemia Miocárdica/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Doença da Artéria Coronariana/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Prognóstico , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
10.
J Nucl Cardiol ; 28(4): 1323-1330, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31385223

RESUMO

PURPOSE: To compare the outputs of a novel all-purpose SPECT camera equipped with CZT detectors (Discovery NM/CT 670) with the state-of-the-art represented by a dedicated CZT (Alcyone, Discovery 530c) cardiac camera in patients submitted to myocardial perfusion imaging (MPI). METHODS: We included 19 patients that underwent sequential low-dose 99mTc-tetrofosmin (148-185 MBq during stress and 296-370 MBq at rest) MPI with Alcyone and Discovery 670 cameras. Quantitative (% tracer's uptake) and semi-quantitative analyses of perfusion data were performed for each scan. Moreover, major left ventricular (LV) functional and structural parameters were derived from each camera and compared. RESULTS: The two cameras showed excellent correlation for segmental myocardial % uptake at stress (R = 0.90; P < 0.001) and at rest (R = 0.88; P < 0.001) with narrow Bland-Altman limits of agreement. The level of diagnostic agreement of Discovery 670 and Alcyone cameras regarding perfusion analysis was excellent (Cohen's κ 0.85). Similarly, the two cameras showed excellent correlation in the evaluation of LV ejection fraction (R = 0.95), peak filling rate (R = 0.97), and mass (R = 0.98). CONCLUSIONS: Our preliminary results suggest that MPI with an all-purpose Discovery 670 CZT-SPECT camera is feasible, comparing well with the current state-of-the-art technology.


Assuntos
Cádmio , Câmaras gama , Cardiopatias/fisiopatologia , Imagem de Perfusão do Miocárdio/instrumentação , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Função Ventricular Esquerda/fisiologia , Zinco , Idoso , Feminino , Cardiopatias/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Volume Sistólico/fisiologia
11.
Phys Med Biol ; 65(22): 225029, 2020 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-33231199

RESUMO

We recently developed a dedicated focusing multi-pinhole collimator for a stationary SPECT system that offers down to 120 µm (or 1.7 nL) spatial resolution SPECT images of cryo-cooled tissue samples (EXIRAD-3D). This collimator is suitable for imaging isotopes that are often used in small animal and diagnostic SPECT such as 125I (27 keV), 201Tl (71 keV), 99mTc (140 keV), and 111In (171 and 245 keV). The goal of the present work is to develop high-resolution pinhole imaging of tissue samples containing isotopes with high-energy photon emissions, for example, therapeutic alpha and beta emitters that co-emit high energy gammas (e.g. 213Bi (440 keV) and 131I (364 keV)) or 511 keV annihilation photons from PET isotopes. To this end, we optimise and evaluate a new high energy small-bore multi-pinhole collimator through simulations. The collimator-geometry was first optimised by simulating a Derenzo phantom scan with a biologically realistic activity concentration of 18F at two system sensitivities (0.30% and 0.60%) by varying pinhole placements. Subsequently, the wall thickness was selected based on reconstructions of a Derenzo phantom and a uniform phantom. The obtained collimators were then evaluated for 131I (364 keV), 213Bi (440 keV), 64Cu (511 keV), and 124I (511 + 603 keV) with biologically realistic activity concentrations, and also for some high activity concentrations of 18F, using digital resolution, mouse knee joint, and xenograft phantoms. Our results show that placing pinhole centres at a distance of 8 mm from the collimator inner wall yields good image quality, while a wall thickness of 43 mm resulted in sufficient shielding. The collimators offer resolutions down to 0.35 mm, 0.6 mm, 0.5 mm, 0.6 mm, and 0.5 mm when imaging 131I, 213Bi, 18F, 64Cu, and 124I, respectively, contained in tissue samples at biologically achievable activity concentrations.


Assuntos
Radioisótopos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Animais , Desenho de Equipamento , Membro Posterior/diagnóstico por imagem , Camundongos , Modelos Teóricos , Imagens de Fantasmas , Fótons , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
12.
Sci Rep ; 10(1): 18616, 2020 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-33122774

RESUMO

We aimed to investigate the image quality of the U-SPECT5/CT E-Class a micro single-photon emission computed tomography (SPECT) system with two large stationary detectors for visualization of rat hearts and bones using clinically available 99mTc-labelled tracers. Sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR) of the small-animal SPECT scanner were investigated in phantom studies using an ultra-high-resolution rat and mouse multi-pinhole collimator (UHR-RM). Point source, hot-rod, and uniform phantoms with 99mTc-solution were scanned for high-count performance assessment and count levels equal to animal scans, respectively. Reconstruction was performed using the similarity-regulated ordered-subsets expectation maximization (SROSEM) algorithm with Gaussian smoothing. Rats were injected with ~ 100 MBq [99mTc]Tc-MIBI or ~ 150 MBq [99mTc]Tc-HMDP and received multi-frame micro-SPECT imaging after tracer distribution. Animal scans were reconstructed for three different acquisition times and post-processed with different sized Gaussian filters. Following reconstruction, CNR was calculated and image quality evaluated by three independent readers on a five-point scale from 1 = "very poor" to 5 = "very good". Point source sensitivity was 567 cps/MBq and radioactive rods as small as 1.2 mm were resolved with the UHR-RM collimator. Collimator-dependent uniformity was 55.5%. Phantom CNR improved with increasing rod size, filter size and activity concentration. Left ventricle and bone structures were successfully visualized in rat experiments. Image quality was strongly affected by the extent of post-filtering, whereas scan time did not have substantial influence on visual assessment. Good image quality was achieved for resolution range greater than 1.8 mm in bone and 2.8 mm in heart. The recently introduced small animal SPECT system with two stationary detectors and UHR-RM collimator is capable to provide excellent image quality in heart and bone scans in a rat using standardized reconstruction parameters and appropriate post-filtering. However, there are still challenges in achieving maximum system resolution in the sub-millimeter range with in vivo settings under limited injection dose and acquisition time.


Assuntos
Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Animais , Osso e Ossos/diagnóstico por imagem , Desenho de Equipamento/instrumentação , Desenho de Equipamento/métodos , Ventrículos do Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Camundongos , Imagens de Fantasmas , Ratos , Tecnécio/administração & dosagem , Tecnécio Tc 99m Sestamibi/administração & dosagem
13.
J Nucl Med Technol ; 48(4): 297-303, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33020236

RESUMO

The D-SPECT is a dedicated cardiac camera that incorporates a solid-state semiconductor detector. This camera differs greatly from conventional SPECT/CT systems, resulting in significant differences in patient imaging. This continuing education article focuses on the specifications of both SPECT/CT and D-SPECT systems, radiopharmaceutical dosing requirements, imaging workflows, and some disadvantages of using each camera system. When used properly, the D-SPECT system can provide high-quality cardiac images with lower doses and faster exam times than conventional SPECT/CT systems.


Assuntos
Coração/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Fluxo de Trabalho , Humanos
14.
Nucl Med Commun ; 41(9): 888-895, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32796477

RESUMO

OBJECTIVES: Myocardial SPECT/CT imaging is frequently performed to assess myocardial perfusion and dynamic parameters of heart function, such as ejection fraction (EF). However, potential pitfalls exist in the imaging chain that can unfavorably affect diagnosis and treatment. We performed a national cardiac quality control study to investigate how much SPECT/CT protocols vary between different nuclear medicine units in Finland, and how this may affect the heart perfusion and EF values. METHODS: Altogether, 21 nuclear medicine units participated with 27 traditional SPECT/CT systems and two cardiac-centered IQ-SPECT systems. The reproducibility of EF and the uniformity of perfusion were studied using a commercial dynamic heart phantom. SPECT/CT acquisitions were performed and processed at each participating unit using their own clinical protocol and with a standardized protocol. The effects of acquisition protocols and analysis routines on EF estimates and uniformity of perfusion were studied. RESULTS: Considerable variation in EF estimates and in the uniformity of perfusion were observed between the units. Uniformity of perfusion was improved in some units after applying the higher count-statistic standard acquisition protocol. EF estimates varied more due to differences in analysis routines than as a result of different acquisition protocols. The results obtained with the two IQ-SPECT systems differed substantially from the traditional multipurpose cameras. CONCLUSION: On average, the EF and heart perfusion were accurately estimated by SPECT/CT, but high errors could be produced if the acquisition and analysis routines were poorly optimized. Eight of the 21 participants altered their imaging protocol after this quality control tour.


Assuntos
Circulação Coronária , Imagem de Perfusão do Miocárdio/instrumentação , Imagens de Fantasmas , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Estônia , Finlândia , Humanos
15.
Phys Med Biol ; 65(19): 195010, 2020 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-32570222

RESUMO

In recent years, breast imaging using radiolabelled molecules has attracted significant interest. Our group has proposed a multi-pinhole molecular breast tomosynthesis (MP-MBT) scanner to obtain 3D functional molecular breast images at high resolutions. After conducting extensive optimisation studies using simulations, we here present a first prototype of MP-MBT and evaluate its performance using physical phantoms. The MP-MBT design is based on two opposing gamma cameras that can image a lightly compressed pendant breast. Each gamma camera consists of a 250 × 150 mm2 detector equipped with a collimator with multiple pinholes focusing on a line. The NaI(Tl) gamma detector is a customised design with 3.5 mm intrinsic spatial resolution and high spatial linearity near the edges due to a novel light-guide geometry and the use of square PMTs. A volume-of-interest is scanned by translating the collimator and gamma detector together in a sequence that optimises count yield from the scan region. Derenzo phantom images showed that the system can reach 3.5 mm resolution for a clinically realistic 99mTc activity concentration in an 11-minute scan, while in breast phantoms the smallest spheres visible were 6 mm in diameter for the same scan time. To conclude, the experimental results of the novel MP-MBT scanner showed that the setup had sub-centimetre breast tumour detection capability which might facilitate 3D molecular breast cancer imaging in the future.


Assuntos
Mama/diagnóstico por imagem , Câmaras gama/normas , Imagens de Fantasmas , Cintilografia , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Feminino , Humanos , Compostos Radiofarmacêuticos
16.
Phys Med Biol ; 65(16): 165015, 2020 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-32369781

RESUMO

There is a tradeoff between spatial resolution and count sensitivity in SPECT with conventional collimators. Multi-pinhole (MPH) collimator technology has potential for concurrent improvement of resolution and sensitivity in clinical SPECT of 'small' organs. This study evaluated a novel MPH collimator specifically designed for dopamine transporter (DAT) SPECT with a triple-head SPECT camera. Count sensitivity was measured with a 99mTc point source placed on the lattice points of a 1 cm grid covering the whole field-of-view (FOV). Spatial resolution was assessed with a Derenzo type hot rod phantom. An anthropomorphic striatum phantom was scanned with total activity representative of a typical patient scan and different striatum-to-background activity concentration ratios. Recovery of striatum-to-background contrast was assessed by the contrast-recovery-coefficient. Measurements were repeated with double-head SPECT with fan-beam or low-energy-high-resolution-high-sensitivity (LEHRHS) collimators. A patient referred to DAT SPECT because of suspicion of Parkinson's disease was scanned with both LEHRHS and MPH collimators after a single tracer injection. The axial MPH sensitivity profile was approximately symmetrical around its peak, although it was shifted 7 cm towards the patient to simplify positioning. Peak sensitivity of the triple-head MPH system in the center of the FOV was 620 cps MBq-1 compared to 225 cps MBq-1 for the double-head fan-beam system. Sensitivity of the MPH system decreased towards the edges of the FOV. The full width of the sensitivity profile at 200 cps MBq-1 was 21 cm transaxially and 11 cm axially. In MPH SPECT of the Derenzo phantom all rods with ≥ 5 mm diameter were clearly visible. MPH SPECT improved striatal contrast recovery by ≥ 20% compared to fan-beam SPECT. The patient scan demonstrated good image quality of MPH SPECT with almost PET-like delineation of putamen and caudate nucleus. SPECT with dedicated MPH collimators provides considerable improvement of the resolution-sensitivity tradeoff in DAT SPECT compared to SPECT with fan-beam or LEHRHS collimators.


Assuntos
Proteínas da Membrana Plasmática de Transporte de Dopamina/metabolismo , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Humanos , Neostriado/metabolismo , Doença de Parkinson/diagnóstico por imagem , Doença de Parkinson/metabolismo , Imagens de Fantasmas
17.
Phys Med Biol ; 65(17): 175001, 2020 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-32369789

RESUMO

Ischemic heart disease remains a significant public health concern, accentuating the importance of basic research and therapeutic studies of small animals in which myocardial changes can be reproducibly detected and quantified. Few or no studies have investigated the performance of microSPECT in quantifying myocardial lesions. We utilized three versions of a multi-compartment phantom containing two left ventricular myocardial compartments (one uniform and one with a transmural 'cold' defect), a ventricular blood pool, and a background compartment, where each version had a different myocardial wall thickness (0.75, 1.0 and 1.25 mm). Each compartment was imaged separately while acquiring list-mode data. The separate compartment data were manipulated into a single data set with a known defect contrast, blood-pool and background activity. Data were processed with background-free defect-contrast values of 0 (no defect), -0.25, -0.5, -0.75, and -1.0 (all defect), three ratios of blood-pool to myocardial activity, 0 (no blood pool activity), 0.1, and 0.2 (20% of the activity in the healthy myocardial compartment), and three ratios of uniform background 0 (no background activity), 0.1 and 0.2, relative to the healthy myocardial compartment. For each wall thickness, defect contrast, blood-pool, and background activity combination, 25 list-mode noise realizations were generated and reconstructed. Volumes of interest were drawn and used to determine mean contrast recovery coefficients (CRCs) over the noise ensembles. We developed a slope-analysis procedure to estimate a single CRC over all contrast levels, with resulting CRC values (for no blood-pool and no background) of 0.848, 0.946, and 0.834 for the 0.75, 1.0, and 1.25 mm wall thicknesses, respectively. We also determined and validated a reprocessing method to calculate an ideal CRC. This work demonstrates the quantitative abilities of microSPECT for myocardial-defect imaging utilizing CRC and establishes a framework for evaluating defect-imaging capabilities in other systems.


Assuntos
Coração/diagnóstico por imagem , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Ventrículos do Coração/diagnóstico por imagem , Humanos
18.
Semin Nucl Med ; 50(3): 219-226, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32284108

RESUMO

Myocardial perfusion imaging (MPI) with Single-Photon Emission Computed Tomography (SPECT) has a major role in the management of coronary artery disease. Recent technological advances regarding SPECT detectors with the use of solid-state detectors has allowed for improved imaging quality since a decade with dramatic dose and/or time reduction of imaging protocols due to improved sensitivity and spatial resolution, and is now performed as a routine exam. Interestingly, this new technology has modified our everyday practice, from acquisition protocols (low dose and ultra-fast protocols) to image semiology. Numerous studies have shown how these technical advances have allowed for improved patient management, with similar or improved diagnostic and prognostic information derived from MPI. These improvements have also led to the straightforward implementation of myocardial blood flow measurement. This article reviews the current status of MPI using new SPECT and SPECT/CT cameras.


Assuntos
Imagem de Perfusão do Miocárdio/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Humanos
19.
Cancer Biother Radiopharm ; 35(7): 520-529, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32182119

RESUMO

Objective: Dose optimization and pharmacokinetic evaluation of α-particle emitting radium-223 dichloride (223RaCl2) by planar γ-camera or single photon emission computed tomography (SPECT) imaging are hampered by the low photon abundance and injected activities. In this study, we demonstrate SPECT of 223Ra using phantoms and small animal in vivo models. Methods: Line phantoms and mice bearing 223Ra were imaged using a dedicated small animal SPECT by detecting the low-energy photon emissions from 223Ra. Localization of the therapeutic agent was verified by whole-body and whole-limb autoradiography and its radiobiological effect confirmed by immunofluorescence. Results: A state-of-the-art commercial small animal SPECT system equipped with a highly sensitive collimator enables collection of sufficient counts for three-dimensional reconstruction at reasonable administered activities and acquisition times. Line sources of 223Ra in both air and in a water scattering phantom gave a line spread function with a full-width-at-half-maximum of 1.45 mm. Early and late-phase imaging of the pharmacokinetics of the radiopharmaceutical were captured. Uptake at sites of active bone remodeling was correlated with DNA damage from the α particle emissions. Conclusions: This work demonstrates the capability to noninvasively define the distribution of 223RaCl2, a recently approved α-particle-emitting radionuclide. This approach allows quantitative assessment of 223Ra distribution and may assist radiation-dose optimization strategies to improve therapeutic response and ultimately to enable personalized treatment planning.


Assuntos
Osso e Ossos/diagnóstico por imagem , Compostos Radiofarmacêuticos/farmacocinética , Rádio (Elemento)/farmacocinética , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Animais , Autorradiografia/métodos , Neoplasias Ósseas/radioterapia , Neoplasias Ósseas/secundário , Osso e Ossos/efeitos da radiação , Humanos , Masculino , Camundongos , Modelos Animais , Imagens de Fantasmas , Neoplasias de Próstata Resistentes à Castração/diagnóstico por imagem , Neoplasias de Próstata Resistentes à Castração/patologia , Neoplasias de Próstata Resistentes à Castração/radioterapia , Radioisótopos/administração & dosagem , Radioisótopos/farmacocinética , Compostos Radiofarmacêuticos/administração & dosagem , Rádio (Elemento)/administração & dosagem , Distribuição Tecidual , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
20.
PLoS One ; 15(3): e0229366, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32142552

RESUMO

A Compton camera is a device for imaging a radio-source distribution without using a mechanical collimator. Ordered-subset expectation-maximization (OS-EM) is widely used to reconstruct Compton images. However, the OS-EM algorithm tends to over-concentrate and amplify noise in the reconstructed image. It is, thus, necessary to optimize the number of iterations to develop high-quality images, but this has not yet been achieved. In this paper, we apply a median filter to an OS-EM algorithm and introduce a median root prior expectation-maximization (MRP-EM) algorithm to overcome this problem. In MRP-EM, the median filter is used to update the image in each iteration. We evaluated the quality of images reconstructed by our proposed method and compared them with those reconstructed by conventional algorithms using mathematical phantoms. The spatial resolution was estimated using the images of two point sources. Reproducibility was evaluated on an ellipsoidal phantom by calculating the residual sum of squares, zero-mean normalized cross-correlation, and mutual information. In addition, we evaluated the semi-quantitative performance and uniformity on the ellipsoidal phantom. MRP-EM reduces the generated noise and is robust with respect to the number of iterations. An evaluation of the reconstructed image quality using some statistical indices shows that our proposed method delivers better results than conventional techniques.


Assuntos
Algoritmos , Simulação por Computador , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Humanos , Método de Monte Carlo , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão de Fóton Único/métodos